• Quick Search:

processing dry processing iron ore

Comments

Condenser Performance Scribd

2013-11-1  PERFORMANCE OF CONDENSER. May 24, 2012 PMI Revision 00 1 Condenser About 50 % heat is lost in condenser For a 200 MW unit 28000 t / hr of CW water is required Slight deterioration in the performance of condenser leads to huge financial loss Normally design value of condenser pressure is 70 mm Hg abs (0.1 Kg abs). May 24, 2012. PMI Revision 00 CONDENSER SPECIFICATIONS

get price

PPT On Steam Condenser SlideShare

2016-7-15  PPT On Steam Condenser 1. Steam condenser By :- lowell harbert 2. Steam condensor Key points :- *Latent heat does not change the temperature. *Sensible heat changes the temprature of the System. sensible heat Water saturated liq. specific

get price

Condenser PDF Scribd

2013-3-16  PERFORMANCE OF CONDENSER Condenser About 50 % heat is lost in condenser For a 200 MW unit 28000 t / hr of CW water is required Slight deterioration in the performance of condenser leads to huge financial loss Normally design value of condenser pressure is 70 mm Hg abs (0.1 Kg abs) 2. CONDENSER SPECIFICATIONS FOR A TYPICAL 200 MW UNIT Type Surface type. single pass

get price

(PDF) The Condenser Performance Test and

The performance of a large industrial condenser was studied and it was found that the main influencing parameters were condenser pressure, flow rate of water through the

get price

(PDF) CONDENSER AND COOLING TOWER

facotrs affecting condenser performance 28-35 and efficiency 3.1 effect of varying the back pressure 28 3.2 effect of air on back pressure 29 3.3 scale formation 30 3.4 effect on vaccum due to various factors 31 3.5 condenser efficiency and performance 34 4.

get price

Thermal performance assessment of steam surface

2019-9-1  Deterioration in thermal performance of condenser not only affects the power generation but also thermal performance of unit as a whole [1,2]. The parameters that are responsible for condenser thermal performance are cooling water (CW) mass flow rate, temperature, heat transfer area, velocity, tube fouling, partially filled water box and air

get price

COOLING TOWERS University of Alabama

2012-1-11  Thermal performance of a cooling tower depends principally on the entering air wet-bulb temperature. The entering air dry-bulb temperature and relative humidity, talcen independently, have an insignificant effect " on thermal verformance of mechanical-draft cooling towers, but do affect the rate of water evaporation in the cooling tower.

get price

Heat Exchanger Fundamentals

2016-9-22  condenser, in which the steam exiting the turbine enters the condenser shell side, and the cool water flowing in the tubes absorbs the heat from the steam, condensing it into water. Large volumes of vapor may be condensed using this type of heat exchanger flow. Figure 5 Cross Flow Heat Exchanger.

get price

5. FANS AND BLOWERS

2017-9-8  A fan operates along a performance given by the manufacturer for a particular fan speed. (The fan performance chart shows performance curves for a series of fan speeds.) At fan speed N 1, the fan will operate along the N 1 performance curve as shown in Figure 5.7. The fan's actu-5. Fans and Blowers

get price

约克变频驱动(VSD)离心式冷水机组(原理及应用).PPT

2016-12-21  Condenser water effects chiller performance in the following way, the lower the ECWT the lower the energy consumption. Good engineers will design for the for worst condition. In most cases this means designing for the highest or second highest temperature bin and the respective entering condenser water temperature.

get price

Performance Analysis of Power Plant Condensers P M V

2015-12-16  Slide 1 Slide 2 Performance Analysis of Power Plant Condensers P M V Subbarao Professor Mechanical Engineering Department I I T Delhi A Device Which makes Power Plant A True

get price

Steam Condenser PowerPoint PPT Presentations

Steam Condensers for Thermal Power Plants Market Size, Average Pricing and Key Regulations to 2020” gives detailed information on the steam condenser market for thermal power plants, focusing both on global and key steam condenser markets. Drivers, restraints, revenue forecast and volume sales are covered for the global market.

get price

(PPT) Condensers and its types (UNIT-2) Ankit Saxena

Condensers and its types (UNIT-2) Steam Condenser and it’s types 1 By: Ankit Saxena Asst. Professor Mangalmay institute of engineering and technology Footer Text 3/25/16 fition: 2 Condenser is a device in which steam is condensed to water at a pressure less than atmosphere. Condensation can be done by removing heat from exhaust steam using

get price

PPT ? AIR COOLED CONDENSER PowerPoint

air cooled condenser air cooled heat exchanger waste heat boiler economizer tubular air heater steam coil air heater compresser intercooler A free PowerPoint PPT presentation (displayed as a Flash slide show) on PowerShow id: 4ed195-YzRiZ

get price

Analysis on Performance of Condenser in Thermal Power

2018-4-24  Ajeet Singh Sikarwar (1988), performance analysis of surface condenser under various operating parameters, International Journal of Engineering Research and Application, Vol.3, issue 4,pp416-421. Cao and Faghri (1983),Transient Two-Dimensional compressible analysis for High-temperature heat pipes with pulsed heat Input, Numerical Heat Transfer

get price

(PDF) The Condenser Performance Test and Thermal

The performance of a large industrial condenser was studied and it was found that the main influencing parameters were condenser pressure, flow rate of water through the condenser, the temperature

get price

UNIT 2 STEAM POWER PLANT Steam Power Plant IGNOU

2011-3-28  2.7 Energy Performance Assessment of Boilers 2.8 Steam Turbines 2.9 Condenser 2.10 Cooling Tower 2.11 Steam Power Station Control 2.12 Summary 2.13 Key Words 2.14 Answers to SAQs 2.1 INTRODUCTION Two important area of application of thermodynamics are power generation and

get price

(PDF) Improving Air-Cooled Condenser Performance in

2006-8-1  A field performance test reported by Chuang & Sue (2005) on an active CCPP with air-cooled condenser showed that CCPP could produce more power output when operating at a lower ambient temperature

get price

4. ENERGY PERFORMANCE ASSESSMENT OF HEAT

2017-9-8  Surface Condenser Ashell and tube exchanger of following configuration is considered being used for Condensing turbine exhaust steam with cooling water at the tube side. Tube Side 20648 Nos x 25.4mmOD x 1.22mm thk x 18300mm long Pitch 31.75mm 60° triangular 1 Pass The monitored parameters are as below: 4. Energy Performance Assessment Of

get price

CHAPTER 17 HEAT EXCHANGERS razifar

2021-3-2  CHAPTER 17 HEAT EXCHANGERS R. K. Shah* and D. R Sekulib University of Kentucky INTRODUCTION A heat exchanger is a device that is used for transfer of thermal energy (enthalpy) between two or more fluids, between a solid surface and a fluid, or between solid particulates and a

get price

The Condenser Performance Test and Thermal

2013-12-24  Condenser is one of the important auxiliary equipments in nuclear power plants. The thermal efficiency of the entire unit was mostly depended on the condenser per-formance. The main factors affect the operation of the condenser performance in the following areas, through the analysis and comparison of the condenser performance impact factors

get price

Steam Condenser PowerPoint PPT Presentations

Steam Condensers for Thermal Power Plants Market Size, Average Pricing and Key Regulations to 2020” gives detailed information on the steam condenser market for thermal power plants, focusing both on global and key steam condenser markets. Drivers, restraints, revenue forecast and volume sales are covered for the global market.

get price

(PDF) The Condenser Performance Test and Thermal

The performance of a large industrial condenser was studied and it was found that the main influencing parameters were condenser pressure, flow rate of water through the condenser, the temperature

get price

HVAC Systems: Overview

2005-12-7  Performance Thermal chillers Absorption Engine-driven Cooling towers Condenser Air cooled Water cooled Microsoft PowerPoint HVACDesignOverviewAREN3050.ppt Author: Brandemuehl Created Date: 12/7/2005 4:41:27 PM

get price

Steam Turbines Performance PDF Chemical Engineering

2018-11-17  STEAM TURBINES PERFORMANCE Free download as Powerpoint Presentation (.ppt), PDF File (.pdf), Text File (.txt) or view presentation slides online. OFF DESIGN PERFORMANCE PREDICTION OF STEAM TURBINES

get price

CHAPTER 17 HEAT EXCHANGERS razifar

2021-3-2  CHAPTER 17 HEAT EXCHANGERS R. K. Shah* and D. R Sekulib University of Kentucky INTRODUCTION A heat exchanger is a device that is used for transfer of thermal energy (enthalpy) between two or more fluids, between a solid surface and a fluid, or between solid particulates and a

get price

Motor Vehicle Air Conditioning (MVAC)

2017-4-26  CONDENSER air flow Check for bent fins or dirt, bugs leaves in front of evaporator Check to make sure cooling fan is operating. Pressure Testing Refrigerant Move gauge or recovery valves fully counter clockwise (OFF position) to prevent refrigerant discharge when you

get price

Practical Steam Turbine Performance Calculations

2018-3-29  Practical Steam Turbine Performance Calculations (using Flex Live’s Steam Flex routine or by manual methods) A steam turbine’s power and/or efficiency can be quickly and accurately calculated using Flexware’s Steam Flex steam properties program. It will be necessary to obtain the following operating data from the field.

get price

PPT Thermodynamics Lecture Series PowerPoint

Condenser?in Throttle Valve Evaporator qin qL Low T Res., TL Outside the house A Schematic diagram for a Heat Pump 48 Second Law. Coefficient of Performance for a Heat Pump; 49 Second Law. Clausius Statement on Refrigerators/Heat Pump; It is impossible to construct a device operating in a cycle and produces no effect other than the

get price

ARI 550.590-98 (chilling water) 豆丁网

2011-10-20  discharge valves specifiedpressure. 3.7.1 Coefficient Performance(COP)[W/W]. coolingcapacity totalpower input anygiven set usually air part-loadefficiency figure meritcalculated per methodrefrigerant condenser may integralpart described 5

get price